• Two, Three or Four Winding Protection for Transformers of All Sizes

    Beckwith Electric's Transformer Protection System M-3311A provides protection, control, monitoring and user interface functions for two, three or four-winding transformers
    June 30, 2008
    2 min read

    Beckwith Electric's Transformer Protection System M-3311A provides protection, control, monitoring and user interface functions for two, three or four-winding transformers. The system includes restrained and unrestrained differential protection, overcurrent protection, and optional voltage, and underfrequency protection. Multiple setpoint groups and user-implementable logic schemes provide flexibility. Dual RS-232 ports and an RS-485 port provide user-interface capabilities.

    Optional modules include the HMI module for front-panel operation and the target module to indicate trip target status and redundant power supply. The M-3311A can be purchased as a differential and overcurrent relay or with the Optional Voltage Protection Package. The M-3826 IPScom Communications Software is included for direct serial or remote communication access. Waveform data can be downloaded using IPScom® while the M-3801D IPSplot PLUS Oscillographic Analysis Software allows for plotting and printing of the downloaded oscillographic data.

    • Generator-Transformer Unit Overall Differential
    • Unit Protection of Other Electrical Apparatus and certain Bus
      Arrangements (including those with a transformer in the zone)
    • Additional Applications: System Backup Protection, Load Shedding
      (voltage and frequency), Bus Protection, and individual Breaker Failure
    • Protection for each winding input
    • Options: Ethernet Connection and Expanded I/O

    Standard Protective Functions

    • Negative-sequence inverse time overcurrent (46)
    • Winding thermal protection (49)
    • Four winding instantaneous phase overcurrent (50)
    • Breaker Failure (50BF)
    • Instantaneous ground overcurrent (50G)
    • Instantaneous residual overcurrent (50N)
    • Four winding inverse time phase overcurrent (51)
    • Inverse time ground overcurrent (51G)
    • Inverse time residual overcurrent (51N)
    • Two, three or four winding phase differential (87T) and high set instantaneous (87H)
    • Ground differential (87GD)
    • IPSlogicTM


    Optional Single-Phase Voltage Protection Package

    • Overexcitation (24) V/Hz, two definite time and one inverse time elements
    • Phase undervoltage (27) function for load shedding
    • Ground Overvoltage (59G)
    • Over/Underfrequency (81O/U)


    Standard Features

    • Eight programmable outputs and six programmable inputs
    • Oscillographic recording
    • Through-Fault Monitoring
    • 10-target storage
    • Real time metering of measured and calculated parameters, including demand currents
    • Two RS-232 and one RS-485 communications ports
    • Standard 19" rack-mount design
    • Removable printed circuit board and power supply
    • 50 and 60 Hz models available
    • 1 or 5 A rated CT inputs available
    • M-3826 IPScom® Communications Software
    • IRIG-B time synchronization
    • Breaker Monitoring
    • Multiple Setpoint Groups
    • Trip Circuit Monitoring
    • Includes MODBUS and DNP 3.0 protocols
    • Summing Currents from mulitple sources for 49, 50, 51, 50N, 51N, 87 GD and Through Fault functions


    Optional Features

    • Redundant Power Supply
    • M-3911A Target Module
    • M-3931 Human-Machine Interface (HMI) Module
    • M-3801D IPSplot® Plus Oscillograph Analysis Software
    • RJ45 Ethernet port utilizing MODBUS over TCP/IP
    • Expanded I/O (8 additional outputs and 12 additional inputs)